Acid Water and Hospital
Infections
Vorobjeva NV, Vorobjeva LI, Khodjaev EY.
Artif Organs.
2004 JunP28(6):590<2.
Department of Physiology of Microorganisms, Biology
Faculty, Moscow State University, Lenin Hills 1/12, Moscow 119992, Russia.
nvvorobjeva@mail.ru
The study is designed to investigate bactericidal
actions of electrolyzed oxidizing water on hospital infections.
Ten of the most common opportunistic pathogens are
used for this study. Cultures are inoculated in 4.5 mL of electrolyzed
oxidizing (EO) water or 4.5 mL of sterile deionized water (control), and
incubated for 0, 0.5, and 5 min at room temperature. At the exposure time of 30
s the EO water completely inactivates all of the bacterial strains, with the
exception of vegetative cells and spores of bacilli which need 5 min to be
killed. The results indicate that electrolyzed
oxidizing water may be a useful disinfectant for hospital infections, but
its clinical application has still to be evaluated. PMID:
15153153 [PubMed < in process]